PRODUCT DESCRIPTION
Sale Zeiss IOL Master 500 , have tested and serviced this IOL 5 to ensure it is operating to the manufacturers specifications. The Zeiss system software is version 5.2.1 and the operating system is Windows XP. The system is complete with the factory calibration test eye, refurbished Brother printer, original Zeiss power table, operator's manual, dust cover, and peripherals.
Your key benefits
- Refractive outcomes you can trust
Distance independent keratometry, robust and repeatable measurements, more than 300 optimized lens constants - Fast and easy to use
Well-designed user interface, plausibility checks, less than 60 seconds for both eyes - Advanced measurements of challenging eyes
> 93% cataract penetration rate2 ; measurement of staphyloma, pseudophakic and silicone-filled eyes, post-LVC formula - Precise and efficient markerless toric IOL alignment
Integral part of ZEISS Cataract Suite, no manual marking steps
IOLMaster 500 Technical Data
| Measurement range | Axial length 14 – 38mm |
| Corneal radii 5 – 10mm | |
| Anterior chamber depth 1.5 – 6.5mm | |
| White-to-white 8 – 16mm | |
| Display scaling | Axial length 0.01mm |
| Corneal radii 0.01mm | |
| Anterior chamber depth 0.01mm | |
| White-to-white 0.1mm | |
| IOL calculation formulas | SRK® II, SRK® / T, Holladay 1 and 2, Hoffer Q, Haigis |
| Clinical history and contact lens fitting method for calculation of corneal refractive power following refractive corneal surgery | |
| Haigis-L IOL calculation for eyes following myopic / hyperopic LASIK / PRK / LASEK surgery | |
| Calculation of phakic anterior and posterior chamber implants | |
| Optimization of IOL constants | |
| Interfaces | Ultrasound data link |
| ZEISS eyecare data management system FORUM | |
| ZEISS computer-assisted cataract surgery system CALLISTO eye via USB or FORUM (DICOM network or EQ Mobile) | |
| Data interface for electronic medical record (EMR) / patient management systems (PMS) | |
| Data export to USB storage media | |
| Export database for Holladay IOL Consultant and HIC.SOAP Pro | |
| Ethernet port for network connection and network printer | |
| Line voltage | 100 – 240 V ± 10 % (self sensing) |
| Line frequency | 50 – 60 Hz |
| Performance consumption | max. 75 VA |